Commit History

Auteur SHA1 Bericht Datum
  TC_Hsu 2bdc77f853 [Workaround][DM30][DW30][CHAdeMO] Workaround for CHAdeMO adapter of Tesla, add CHAdeMO communication permission retry function. 4 jaren geleden
  TC_Hsu 53a77d83a6 [Improve][DM30][DW30][firmware version] For CCS formal firmware version, the web page should not display redundant '.' character. 4 jaren geleden
  TC_Hsu f1903a429e [Bug fixed][DM30][DW30][event code] Fix the bug that "023892" event code will be cleaned if the charger in idle state. If QCA7000 data not installed, it is impossible to recovery the fault, unless someone shutdown the charger and install the QCA7000 data. After DCM received "023892", it should show fix page. 4 jaren geleden
  TC_Hsu 63226710cf [Merge][DM30][DW30][Full function]: Merge DS60 V0.16 application source code 4 jaren geleden
  TC_Hsu e0ab71f89c [Bug fixed][DM30][DW30][OCPP smart charhing]: If OCPP backend not connected, the charging current will be 0A when charging. 4 jaren geleden
  TC_Hsu 293ddfc098 [Improve][DM30][DW30][General]: For good reading and debug use, correct some indent and space in source code files. 4 jaren geleden
  TC_Hsu b35e2dec20 [Bug fixed][DM30][DW30][OCPP smart charging]: The OCPP smart charging current limit value is no march the value setup by txprofile. 4 jaren geleden
  TC_Hsu 0ab92d678c [New feature][DM30][DW30][OCPP]: Implement smart charging limitation feature. 4 jaren geleden
  TC_Hsu 6c96b818ba [Improve][DM30][DW30][EV communication]: Modify the GFD status message for EV board 4 jaren geleden
  TC_Hsu ebc5c98869 [Improve][DM30][DW30][EV communication]: Improve debug information and variable initialize in Module_EvComm. 4 jaren geleden
  TC_Hsu 5bcecc8594 [Bug fixed][DM30][DW30][Web page]: In web page, the unit of DC charging voltage and current is 0.1V and 0.1A, it should be 1V and 1A. 4 jaren geleden
  TC_Hsu 34fc342bb1 [Improve][DM30][DW30][EV Communication]: Improve CCS EV board firmware version parsing method. 4 jaren geleden
  TC_Hsu 53d2c44d93 [Bug fixed][DM30][DW30][Event code]: After EV board send the alarm code "000000" to DCM, the following alarm code will not displayed and stored. 4 jaren geleden
  TC_Hsu 4a858af698 [New feature][DM30][DW30][Event code]: Add three new CCS alarm code 023850/023891/023892 4 jaren geleden
  TC_Hsu cffbc2c4dd [Improve][DM30][DW30][General]: Improve log print out method. 4 jaren geleden
  TC_Hsu 3b6b183d0e [Improve][DM30][DW30]: Remove the unnecessary if case to update the PresentMsgFlowStatus of CHAdeMO. 4 jaren geleden
  TC_Hsu b73fdcdac0 [Bug fixed][DM30][DW30][Charging info]: The present charged duration should not be the remain charging duration, vice versa. 4 jaren geleden
  TC_Hsu 92ddec9feb 2020.06.05 / TC Hsu 4 jaren geleden
  TC_Hsu 70bc72b5b9 2020.06.01 / TC Hsu 4 jaren geleden
  FolusWen 070e4353b9 2020.02.20 / Alston 5 jaren geleden
  7899 876a31ba49 2020-01-13 / Yuanda 5 jaren geleden