TC_Hsu
|
2bdc77f853
[Workaround][DM30][DW30][CHAdeMO] Workaround for CHAdeMO adapter of Tesla, add CHAdeMO communication permission retry function.
|
4 years ago |
TC_Hsu
|
53a77d83a6
[Improve][DM30][DW30][firmware version] For CCS formal firmware version, the web page should not display redundant '.' character.
|
4 years ago |
TC_Hsu
|
f1903a429e
[Bug fixed][DM30][DW30][event code] Fix the bug that "023892" event code will be cleaned if the charger in idle state. If QCA7000 data not installed, it is impossible to recovery the fault, unless someone shutdown the charger and install the QCA7000 data. After DCM received "023892", it should show fix page.
|
4 years ago |
TC_Hsu
|
63226710cf
[Merge][DM30][DW30][Full function]: Merge DS60 V0.16 application source code
|
4 years ago |
TC_Hsu
|
e0ab71f89c
[Bug fixed][DM30][DW30][OCPP smart charhing]: If OCPP backend not connected, the charging current will be 0A when charging.
|
4 years ago |
TC_Hsu
|
293ddfc098
[Improve][DM30][DW30][General]: For good reading and debug use, correct some indent and space in source code files.
|
4 years ago |
TC_Hsu
|
b35e2dec20
[Bug fixed][DM30][DW30][OCPP smart charging]: The OCPP smart charging current limit value is no march the value setup by txprofile.
|
4 years ago |
TC_Hsu
|
0ab92d678c
[New feature][DM30][DW30][OCPP]: Implement smart charging limitation feature.
|
4 years ago |
TC_Hsu
|
6c96b818ba
[Improve][DM30][DW30][EV communication]: Modify the GFD status message for EV board
|
4 years ago |
TC_Hsu
|
ebc5c98869
[Improve][DM30][DW30][EV communication]: Improve debug information and variable initialize in Module_EvComm.
|
4 years ago |
TC_Hsu
|
5bcecc8594
[Bug fixed][DM30][DW30][Web page]: In web page, the unit of DC charging voltage and current is 0.1V and 0.1A, it should be 1V and 1A.
|
4 years ago |
TC_Hsu
|
34fc342bb1
[Improve][DM30][DW30][EV Communication]: Improve CCS EV board firmware version parsing method.
|
4 years ago |
TC_Hsu
|
53d2c44d93
[Bug fixed][DM30][DW30][Event code]: After EV board send the alarm code "000000" to DCM, the following alarm code will not displayed and stored.
|
4 years ago |
TC_Hsu
|
4a858af698
[New feature][DM30][DW30][Event code]: Add three new CCS alarm code 023850/023891/023892
|
4 years ago |
TC_Hsu
|
cffbc2c4dd
[Improve][DM30][DW30][General]: Improve log print out method.
|
4 years ago |
TC_Hsu
|
3b6b183d0e
[Improve][DM30][DW30]: Remove the unnecessary if case to update the PresentMsgFlowStatus of CHAdeMO.
|
4 years ago |
TC_Hsu
|
b73fdcdac0
[Bug fixed][DM30][DW30][Charging info]: The present charged duration should not be the remain charging duration, vice versa.
|
4 years ago |
TC_Hsu
|
92ddec9feb
2020.06.05 / TC Hsu
|
4 years ago |
TC_Hsu
|
70bc72b5b9
2020.06.01 / TC Hsu
|
4 years ago |
FolusWen
|
070e4353b9
2020.02.20 / Alston
|
5 years ago |
7899
|
876a31ba49
2020-01-13 / Yuanda
|
5 years ago |