Explorar o código

2021-02-18 / Eason Ynag
Action
1. Fixed : check alarm status and check info status recovered logic.

File
1. Module_EventLogging.c

8009 %!s(int64=4) %!d(string=hai) anos
pai
achega
7edef692b6
Modificáronse 1 ficheiros con 2 adicións e 2 borrados
  1. 2 2
      EVSE/Modularization/Module_EventLogging.c

+ 2 - 2
EVSE/Modularization/Module_EventLogging.c

@@ -467,7 +467,7 @@ int main(void)
 						if(((tmp>>BitCount)&0x01)==0)//Recovered
 						{
 							EventCodeTmp[0]='1';
-							ShmStatusCodeData->AlarmCode.PreviousAlarmVal[ByteCount]&=(0<<BitCount);
+							ShmStatusCodeData->AlarmCode.PreviousAlarmVal[ByteCount]&=~(1<<BitCount);
 							RemoveFaultCodeToBuf(EventCodeDisp);
 						}
 						else
@@ -499,7 +499,7 @@ int main(void)
 						if(((tmp>>BitCount)&0x01)==0)//Recovered
 						{
 							EventCodeTmp[0]='1';
-							ShmStatusCodeData->InfoCode.PreviousInfoVal[ByteCount]&=(0<<BitCount);
+							ShmStatusCodeData->InfoCode.PreviousInfoVal[ByteCount]&=~(1<<BitCount);
 							RemoveFaultCodeToBuf(EventCodeDisp);
 						}
 						else