123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260 |
- libmodbus 2.9.5 (2011-06-XX)
- ============================
- - Revert libmodbus licence from LGPLv3 to LGPLv2.1 to avoid
- incompatibility with GPLv2 program. This change has been approved
- by Tobias Doerffel, Florian octo Forster and Hannu Vuolasaho.
- - Enable RS485 support only when available
- - Export modbus_set/get_serial_mode functions on all platforms
- - API change for read/write multiple registers function:
- * modbus_read_and_write_registers -> modbus_write_and_read_registers
- The function name was confusing because the write operation is performed
- before the read. Take care to swap the arguments in the migration process.
- - Documentation of modbus_write_and_read_registers, modbus_mapping_new/free,
- report_slave_id. modbus_get_byte_from_bits, modbus_set_bits_from_byte(s),
- modbus_[gs]et_float, modbus_reply and modbus_reply_exception.
- - Enhanced report slave ID
- libmodbus 2.9.4 (2011-06-05)
- ============================
- - IPv6 support
- Make the TCP implementation "protocol independent" by Florian Forster
- and Stéphane Raimbault.
- - Fix compilation on Windows 7 (x64) with MinGW/MSYS and GCC 4.5
- Reported by Patsy Kaye.
- - Documentation of libmodbus functions with AsciiDoc (man and HTML) by Stéphane
- Raimbault
- - Avoid an iteration in flush function
- - New functions to send and receive raw requests (modbus_send_raw_request,
- modbus_receive_confirmation)
- - Fix flush function of TCP backend on Windows
- - API changes for server/slave:
- * modbus_receive doesn't take socket/fd argument anymore
- * new function modbus_set_socket to set socket/fd
- - API changes for timeout functions:
- * modbus_get_timeout_begin -> modbus_get_response_timeout
- * modbus_set_timeout_begin -> modbus_set_response_timeout
- * modbus_get_timeout_end -> modbus_get_byte_timeout
- * modbus_set_timeout_end -> modbus_set_byte_timeout
- - Fix longstanding limitation of server to wait forever
- - New functions modbus_set/get_serial_mode by Manfred Gruber and Stéphane
- Raimbault for RS485 communications
- - Improved recovery mode (see modbus_set_error_recovery documentation) for
- data link and protocol errors.
- - Fix compilation issue with Microsoft Visual Studio 2008.
- Reported by Allan Cornet.
- libmodbus 2.9.3 (2011-01-14)
- ============================
- - Major rewriting of the message reading (no more timeouts on exception)
- by Stéphane Raimbault
- - New function to reply to an indication with an exception message
- modbus_reply_exception()
- - New function modbus_get_header_length(modbus_t *ctx)
- - New functions to manipulate data:
- * MODBUS_GET_INT32_FROM_INT16
- * MODBUS_GET_INT16_FROM_INT8
- * MODBUS_SET_INT16_TO_INT8
- - Fix GH-2. Read/write were swapped in _FC_READ_AND_WRITE_REGISTERS
- - Install an ignore handler for SIGPIPE on *BSD
- Original patch by Jason Oster.
- - Fix closing of Win32 socket.
- Reported by Petr Parýzek.
- - Fix unit identifier not copied by the TCP server.
- Reported by Antti Manninen.
- - Fix missing modbus_flush() in unit tests
- - Fixes for OpenBSD by Barry Grumbine and Jason Oster
- libmodbus 2.9.2 (2010-12-05)
- ============================
- - Win32 support by Tobias Doerffel
- - Split source code around RTU and TCP (backends)
- - Rename modbus_[listen|accept] to modbus_tcp_[listen|accept]
- - Remove slave argument from modbus_new_rtu()
- - Check received function code
- - Fix segfault in bandwidth-server-many-up on inet_ntoa() call
- - Fix unit test of report slave ID in RTU
- - Fix GH-3. Remove inclusion of config.h in modbus.h
- - Correctly detect if we are cross-compiling for win32 by Kirill Smelkov.
- - Fix setting of the broadcast address
- libmodbus 2.9.1 (2010-08-16)
- ============================
- - Brand new API (see MIGRATION notes)!
- - Remove the internal function set_message_length_tcp
- - Restore slave ID (server ID) argument in functions
- - Error conventions of POSIX systems and error recover
- - Parity setting is now a single char ('N', 'E' or 'O')
- - Report slave ID server side
- - OpenBSD support by Anibal Limón.
- - New read and write registers function by Hannu Vuolasaho.
- - Versioning infrastructure
- Inspired by the Clutter project and the work done by Florian Forster.
- - Fix the broadcast constant (255 -> 0)
- Reported by David Olivari.
- - Fix #463299 - New functions to define the timeouts of begin and end of trame
- Original patch by Sisyph (eric-paul).
- - Fix #591142 - Slave id check should be disabled in TCP connection
- Reported by aladdinwu.
- libmodbus 2.1.0 (2010-03-24)
- ============================
- - New API to read and write float values by Stéphane Raimbault and Florian
- Forster.
- - New API for slave server (see MIGRATION)
- - New slave server able to handle multiple connections
- - Slave only replies to broadcast queries or queries with its slave ID
- - Improved Modbus protocol conformance
- - modbus_param_t is smaller (2 int removed)
- - Better error management and SIGPIPE signal is blocked
- - Faster
- - Fix #333455 - Cygwin IPTOS_LOWDELAY not supported on cygwin
- Reported by Jeff Laughlin and Yishin Li.
- - Fix #375926 - modbus.c:164: error: `MSG_DONTWAIT' undeclared
- Reported and tested by Yishin Li.
- - Fix #378981 - CRC error on RTU response doesn't return negative value
- Reported by Henrik Munktell.
- - Fix report slave ID request
- Patch (bzr) provided by Paul Fertser.
- - Fix #425604 - Conditional jump or move depends on uninitialised value(s)
- Occurs on first occurence of slave timeout.
- Reported by Henrik Munktell.
- - Fix #457200 - FreeBSD support
- Patch provided by Norbert Koch.
- Other changes:
- - The code is now published and developed on
- http://github.com/stephane/libmodbus
- - Waf support has been removed
- libmodbus 2.0.3 (2009-03-22)
- ============================
- - Fix CRC error when a slave RTU send a response.
- Thanks to Justin Carroll to have reported and tested my patch.
- - Remove an assignment in compute_response_length()
- - Remove duplicate counter in read_io_status()
- - Fix #274511 reported by 'Kylesch'
- Invalid error check in modbus_init_listen_tcp
- libmodbus 2.0.2 (2008-08-10)
- ============================
- - Fix a bug reported by email by Davide Pippa
- The function modbus_receive must check the number of values
- indicated in the response accordingly to the query.
- - Fix #241006 reported by Jesus Hernandez Tapia
- modbus_check_response() crashes on an invalid exception code
- - Reduce the number of function calls (read_reg_response and
- preset_response have been removed)
- - Add a new unit test for bad response
- - Catch the timeout even if the length is equal to a exception trame
- - Test only msg_length_computed on change
- - Many comments and cleanups
- libmodbus 2.0.1 (2008-07-02)
- ============================
- - Include libmodbus.spec in the tarball
- - Fix #241006 reported by Jesus Hernandez Tapia
- modbus_check_response() crashes on an invalid exception code
- libmodbus 2.0.0 (2008-05-18)
- ============================
- - Slave API
- https://blueprints.launchpad.net/libmodbus/+spec/slave-api
- - No more glib dependency
- https://blueprints.launchpad.net/libmodbus/+spec/glib-dependency
- - Unit testing and many test programs
- - Waf build support
- https://blueprints.launchpad.net/libmodbus/+spec/waf-support
- - MacOS X support by Matthew Butch
- https://blueprints.launchpad.net/libmodbus/+spec/macosx-support
- - Unit testing (unit-test-slave and unit-test-master)
- - Port number is now defined at initialisation by Dirk Reusch
- - Better memory management (uint8_t *data and packing of
- modbus_param_t)
- - Better error management
- - Declare many static functions and const arrays
- - Enhance an integer division
- - The GNU licences LGPL and GPL are in version 3
- - Debian and RPM packages (#224496)
- - Many cleanups
- - Fix #159443 reported by Stefan Bisanz
- Index of incoming data in force multiple coils function
- - Fix #161989 reported by Konstantinos Togias
- Serial device paths more than 10 chars long (eg. /dev/ttyUSB0) don't
- fit to modbus_param_t -> device char[11] var.
- - Fix #188189 reported by Chris Hellyar
- Compute_response_size() no entry for read_input_status()
- - Fix #191039 reported by Todd Denniston
- modbus.h is not installed at prefix.
- - Fix #211460 reported by Todd Denniston
- With TCP, automatic reconnect on error may not be desired.
- - Fix #224485 reported by Todd Denniston
- libmodbus does not link with c++ code.
- - Fix #224496 reported by Todd Denniston
- It is easier to install on rpm based systems with a spec file.
- libmodbus 1.2.5 (2008-05-18)
- ============================
- - Fix #224485 reported by Todd Denniston
- libmodbus does not link with c++ code.
- libmodbus 1.2.4 (2008-03-14)
- ============================
- - Fix #191039 reported by Todd Denniston
- modbus.h is not installed at prefix.
- libmodbus 1.2.3 (2008-02-03)
- ============================
- - Fix #188189 reported by Chris Hellyar
- Compute_response_size() no entry for read_input_status()
- - Fix #181887 reported by Jesus Hernandez Tapia.
- Slave address in build_request_packet_tcp() is hardcoded as 0xFF.
- libmodbus 1.2.2 (2007-11-12)
- ============================
- - Fix #161989 reported by Konstantinos Togias
- Serial device paths more than 10 chars long (eg. /dev/ttyUSB0) don't
- fit to modbus_param_t -> device char[11] var.
- - Structure is also bit better 'packed' to conserve memory (see the
- trunk for a real enhancement).
- libmodbus 1.2.1 (2007-11-02)
- ============================
- - Fix #159443 reported by Stefan Bisanz
- Index of incoming data in force multiple coils function
- - Deleted useless code in check_crc16()
- - Untabify source code
- - Changed author's email to Stéphane Raimbault
- libmodbus 1.2.0 (2007-05-10)
- ============================
- - FIX Compilation GCC-4.0
- - Project name in autogen.sh
|