# modbus_read_input_bits ## Name modbus_read_input_bits - read many input bits ## Synopsis ```c int modbus_read_input_bits(modbus_t *ctx, int addr, int nb, uint8_t *dest); ``` ## Description The *modbus_read_input_bits()* function shall read the content of the `nb` input bits to the address `addr` of the remote device. The result of reading is stored in `dest` array as unsigned bytes (8 bits) set to `TRUE` or `FALSE`. You must take care to allocate enough memory to store the results in `dest` (at least `nb * sizeof(uint8_t)`). The function uses the Modbus function code 0x02 (read input status). ## Return value The function shall return the number of read input status if successful. Otherwise it shall return -1 and set errno. ## Errors - *EMBMDATA*, too many discrete inputs requested ## See also - [modbus_read_input_registers](modbus_read_input_registers.md)